USER’S MANUALDS-EQ230 Dual Channel 30 Band EQUSBUSB(482mm)19"DIGITALDIGITAL®DS -EQ 230L INR INL OUTR OUTL COMPR COMP
By pressing the ENTER button and then using the “NAV/PM1” encoder the following pages can be accessed:Recall a Program: this page allows the Loading o
Once loaded, the DS-EQ230 will exit to the “Recall a Program” screen automatically and the above screen will disappear:Note: At any time it is possibl
To store the Preset Name press the “ENTER” button again.The above action will take you to the “Enter to Save” page showing the selected location for t
By pressing the ENTER button and rotating the “PM2” or “PM3” encoder, it is possible to scroll through the previously saved presets and the available
Interface Utilities Sub-menu - this sub-menu allows you to define the remote control interface[USB or RS485] to be used for controlling the DS-EQ230 :
Security Sub-menu - this sub-menu allows the User to set the parameters shown, lock theDS-EQ230 and set a Password, therefore limiting the unit's
User Password: from the “User Password” sub-menu:Press “ENTER” to access the “User Password” page:Using the “PM2” or “PM3” encoders to choose a charac
Enable Password: from the “Enable Password” sub-menu:Press “ENTER” to gain access to the “Enable Password” screen:Once a Password has been entered int
• Menu “LIN/RIN” Equalizer’s Channels Editing [access by pushing the “LIN/RIN” buttons]From the “Default Screen”, it is possible to access the “LI
Source page - from this page it is possible to assign one of the following Inputs to any Equalizer’s Channel:1. Analog InA = Input Channel A2. Analog
1ContentsContentsIntroductionIntroductionThank you for choosing a Galaxy DSPOT Digital Signal Processor. You have joined hundreds of thousands of othe
Delay page - from this page it is possible to set the Equalizer’s Channels Delay Time from000.000mS up to 848.9984mS, by steps of 1mS or 20.8uS.To set
LPF sub-menu - from this sub-menu it is possible to set the Equalizer’s Channels Low Pass Filter (LPF).The following is an example of a LPF sub-menu s
The DS-EQ230 allows the user to select either Bell or Shelving Parameters and assign themindependently using the 30 available filters.In order to sele
Once in the Bell Filter’s edit screen all the filter's parameters can be modified using the “NAV/PM1”, “PM2” and “PM3” encoders for editing the F
Note: Once the desired High Shelving filter is selected, the “PM3” can then be used to select thedesired GAIN and when the GAIN is set at a value diff
• MENU “A and B Output Channels Compressor/Limiter” [Access by pushing the“LCOMP/RCOMP” buttons]From the “Default Screen”, it is possible to access th
• MENU “A and B Output Channels Utilities” [Access by pushing the “LOUT/ROUT” buttons]From the “Default Screen”, it is possible to access the “Equali
• Factory ResetIn the event of the password being lost or any other reason, the user may require the unit to beReset to the original factory settings.
• Equalizer’s Channels LIN/RIN and Compressor/Limiter’s Channels LCOMP/RCOMP Last Edited Parameter Return FunctionOnce you have escaped out of param
Using the DS-EQ230 Software.lLoad the Software “SetupDS-EQ230V1.0.0” either with the included CD or via the Galaxy Website.lDouble click on “Setup”, c
2Safety InstructionsSafety Instructions! IMPORTANT SAFETY INSTRUCTIONS !READ these instructions.KEEP these instructions.HEED all warnings.FOLLOW all i
The Main Page will load.The software will look for active devices and show them in a list.To edit Double click on the desired device in the ID list.29
You can name a device by selecng edit device name.From the main page you can choose the secon you want to adjust by clicking on the associated block
Select the gain block to access the gain and polarity of the inputs and outputs.31
Select the Delay block to access the input and output delays.Select the PEQ block to access the input and output filters.32
Select the Limiter Block to access the Limiter page.33
You can select the meters to show either, level or limiter function.You can select and edit the noise generator functions.You can copy parameters betw
• USB/RS485 Remote Control protocol for Preset Changing and Gain/Volume controlsThe following is the HEX Code for controlling the DS-EQ230 recall pre
RX:Input Gain and Output Volume Control:UPDATE GAINS-PHASE: CMD=01HA. The User has to send the following Command, including the value to be assigned t
USB• DS-EQ230 Technical SpecificationsThe DS-EQ230 Digital Graphic/Parametric Equalizer is based on a powerful analog and digital DSP platform having
Overview®DS -EQ 23 0L INR INL OUTR OUTL COMPR COMPDescribed below are the functions of the front panel control buttons and encoders for the DS-EQ230.1
1-800-369-7768 www.galaxyaudio.com V02072014Printed in China© Copyright Galaxy Audio 2014WARRANTY Information can be viewed online athttp:/
As soon as the DS-EQ230 is turned ON the device model name will appear in the LCD screen:A status bar will show the progress of the DS-EQ230 initializ
• Encoders and ENTER, ESC buttonsThe DS-EQ230 is equipped with 3 Relative Encoders, “NAV/PM1”, “PM2” and “PM3”. Theseencoders allow you to navigate
• DS-EQ230 Menu and Sub-Menu StructuresAs stated above, the start-up default screen is the following factory preset:From this point, sub-menus are a
From the “System Utilities Sub-menu”, pushing “ENTER” and then using the “NAV/PM1” encoder for scrolling will give access to the following pages: - P
Ramps on changes: this page allows you to activate or de-activate Fading-in and Fading-outramps on the input/output volumes when any parameter changes